Pay special attention to the.
Moisture cabinet concrete floor.
As it evaporates more moisture moves up through these pathways in a cycle and forms a gradient effect within the slab.
A third option a simple diy test can indicate the presence of excess moisture either on the slab surface or in the room s air but it cannot measure the amount of moisture.
The reason for this is that concrete is a very porous material meaning that water can rise through capillaries and therefore lead the property to suffer from having damp floors.
One of the simplest most economical test methods for determining whether there may be moisture in concrete is the astm d 4263 concrete moisture test.
Moisture within a concrete slab follows a number of small pathways or capillaries that form as it combines with the initial mix elements cement aggregate and any other admixtures.
2 left thumbs oct 7 16 at 19 38.
Tile flooring moisture warning signs.
If excess moisture is present in a concrete slab when an impermeable surface treatment is installed it will become trapped under that covering.
Alternatively if rebar within the concrete is too wet it could rust and contribute to spalling as well.
These problems are not only disrupting functions of the building due to maintenance operations but also costly.
Main things i would avoid are resting the raw ends of your cabinet sides on the concrete or floor where they can wick up moisture.
Commonly concrete floors are vulnerable to moisture and suffer from different detrimental influence of moisture such as lifting tile off the floor rotting hardwood damping carpet coating delamination and many more.
Use a sealer designed for concrete moisture protection such as an epoxy concrete sealer which often comes in two parts that must be mixed immediately before applying.
Flooring manufacturers rate their products based on the moisture levels they can tolerate and testing your slab can tell you if a particular flooring material is likely to perform adequately.
Duct tape an 18 inch square piece of plastic onto the exposed concrete and leave it for 16 hours.
Jacob edmond oct 7 16 at 19 02 it seems like the ideal solution then would be to stop the flooring shy of the cabinets and use the feet composit shims to lift the cabinets off the slab.
Floors can easily suffer from moisture ingress otherwise known as penetrating damp.
Over time hydrostatic pressure will force that moisture upwards and can cause bubbles in surface treatments and cracks in covering materials that are installed above it.